Crucible effective capacity (Steel)20KGMax temperature1800CMax melting vacuum7x10-3Pa
Specification:
Crucible effective capacity (Steel) | 20KG |
Max temperature | 1800C |
Max melting vacuum | 7x10-3Pa Vacuum time: open diffusion pump when preheating is complete, then up to 7x10-3Pa within 30 minutes. |
Rated power | 60KW |
Rated voltage | 375V |
Power frequency | 50HZ |
Rated frequency | 1500~2500HZ |
Heat element | Induction copper coil |
Vacuum system |
70L/s Double stage Rotary vane mechanical pump Dia.300mm diffusion pump, Max. pumping speed: 5000L/s Dia.300mm diffusion pump cooling trap. Dia.300mm diffusion pump flapper valve + Dia.80mm former pump flapper valve Stainless pipe + stainless bellows |
Warranty
Warranty | One year limited warranty with life time support. (Consumable parts such as heater and crucibles are not covered by the warranty, please order the replacement at related products) |
Free technical support | Lifetime |
Value-added services |
Sample test: We have a sample lab to offer you free sample test. According to your requirement, we can test the material, process, etc. Save your time and money, good for your project. Technical consultant: We offer free technical consultant regarding furnace, heater, heating-treatment, etc. |
Standard size
Model | Capacity | Power |
JHR-LL-5 | 5kg | 40KW |
JHR-LL-10 | 10KG | 40KW |
JHR-LL-20 | 20KG | 60KW |
JHR-LL-25 | 25KG | 75KW |
JHR-LL-50 | 50KG | 150KW |
JHR-LL-100 | 100KG | 250KW |
JHR-LL-200 | 200KG | 350KW |
JHR-LL-300 | 300KG | 500KW |
JHR-LL-500 | 500KG | 700KW |